TM 9-2330-381-14
4-10.
PMCS (CONT)
Q - Quarterly
S - Semiannually
A - Annually
Item
Interval
ITEM TO BE INSPECTED
no.
QSA
Procedure
4
PLATFORM WELDMENT
Check entire platform for wear, cracks, broken or
defective welds, loose or missing hardware, deformed
components, rust, or corrosion. Repair as required.
Refer defective welds to DS maintenance.
5
BATTERY
WARNING
Do not wear watches, rings, or other jewelry
which could short out battery terminals while
servicing battery. Do not smoke or use open
flame around batteries. Battery may explode
from a spark. Battery acid is harmful to skin
and eyes. Wear protective goggles to prevent
injury to personnel when working with batteries.
Disconnect or remove battery (16) as required
necessary, remove corrosion with wire brush,
followed by a solution of sodium bicarbonate (item
22, appx. E) and water. After cleaning, apply
petroleum jelly (item 17, appx. E) to terminals.
Reconnect or install battery (16) as required
4-14 Change 1