TM 9-2330-381-14
8.
Slide heat shrink tubing over both quick-disconnect plugs and diode (8). Using soldering torch kit, shrink heat
shrink tubing over quick-disconnect plugs and diode.
9.
On glow-plug type indicator, using APU electrical schematic (figure FO-4) as a guide, reconnect jumper wire (10)
to glow plug indicator (11) and starter switch (7) terminal GL.
10.
Aline and install access plate (5) to APU control box and secure with four screws (3) and lockwashers (4).
11.
Raise cover weldment (2) and secure to APU control box by rehooking retainer (1).
FOLLOW-ON MAINTENANCE
Perform APU starting and check glow plug indicator for proper operation (para. 2-16).
4-33.
HYDRAULIC CONTROL MODULE JUMPER WIRES
This task covers:
a. Removal
c. Repair
b. Inspection
d. Installation
INITIAL SETUP
Tools
General mechanics tool kit, item 16, appx. B
The following tools can be found in common tool kit no. 2, item 18, appx. B:
Soldering gun
Electrical repair kit
Creeper, mechanics
Extension light, 24 ft
Measuring tape
Materials
Lockwasher (4)
Lockwasher
Electrical insulation sleeving, item 22, appx. E
Personnel Required: 2
Equipment Condition
Intervehicular cables disconnected, wheels chocked, and front and rear support legs lowered supporting platform
Change 1 4-132.1/(4-132.2 blank)