TM 9-2330-381-14
4-49.
CAUTION
Apply pipe sealant compound to the all male pipe threads of pneumatic fittings,
using only enough compound to coat the threads. Do not allow compound to
enter a component/fitting or the compound may restrict/block air passages and
damage to equipment or equipment failure may result.
Note positioning/orientation of fittings on the illustrations. It is important to have
the tightened fittings positioned as shown so that hoses are not too short and
fittings do not interfere with one another or damage to equipment may result.
4.
Apply pipe sealant compound to male threads of fittings. Remove caps/plugs and install two pipe-to-tube elbows
(116 and 115) to platform (air tank) weldment.
5.
Aline and install two loop clamps (114) onto weld studs and secure with two lockwashers (113) and nuts (112).
6.
Aline and install two loop clamps (111) onto weld studs and secure with two lockwashers (110) and nuts (109).
7.
Apply pipe sealant compound to male threads of fittings. Remove caps/plugs and install two pipe-to-tube elbows
(108 and 107) to platform (air tank) weldment.
8.
Apply pipe sealant compound to male threads of fittings. Remove caps/plugs and install pipe-to-tube elbow (106),
pipe elbow (105), check valve (104), and pipe-to-tube elbow (103) to platform (air tank) weldment.
4-228 Change 1