TM 9-2330-381-14
3.
Using a drain pan, tag and disconnect hydraulic tube (5) from straight pipe-to-tube adapter (6) on pressure gage
(7).
4.
Remove three self-locking nuts (8), screws (9), and pressure gage (7). Remove straight pipe-to-tube adapter (6)
from pressure gage (7). Discard self-locking nuts. Install caps/plugs into openings.
5.
Repeat steps 4 and 5 to remove three remaining pressure gages (7), as required.
4-433