TM 9-2330-381-14
5-21.
HYDRAULIC CONTROL MODULE FRAME
This task covers:
a. Removal
c. Assembly
b. Disassembly
d. Installation
INITIAL SETUP
Tools:
Suitable lifting device, 2,000 lb minimum capacity
General mechanics tool kit, item 16, appx. B
The following tools can be found in field maintenance basic tool kit, item 14, appx. B:
Drain pan, 4 gal capacity
Wrench, combination, 1-1/4"
Creeper, mechanic's
Gloves, chemical and oil protective
Extension light, 24 ft
Jack, hydraulic, transmission
Goggles, industrial
Materials/Parts
Dry cleaning solvent, item 26, appx. E
Lockwasher (6)
Lockwasher (3)
Lockwasher (3)
Cotter pin
Personnel Required: 2
Equipment Condition
General Safety Instructions
WARNING
Hydraulic fluid may be hot if system has been in operation. Allow time for system
to cool before performing maintenance or injury or burns to personnel may result.
Residual pressure may remain in hydraulic lines. Open fittings slowly or injury to
personnel may result.
Hydraulic fluid may be absorbed through the skin. Wear long sleeves, gloves, and
goggles or face shield. If hydraulic fluid gets into the eyes, flush them immediately
with water and seek medical attention. If hydraulic fluid gets on skin, thoroughly
wash with soap and water. Wash hands thoroughly prior to eating or smoking.
5-90