TM 55-1925-282-14&P
0009 00
No Fresh Water Flow
During Fresh Water
Flush Cycle
Is
there any
No
Perform procedure 1
indication of power
of this work package.
at the system
controller?
Yes
Is the
At the applicable system
Secure all power to the applicable
SYSTEM
controller:
No
ROWPU for 30 seconds to allow the
OFF indicator lit
1. Press the STOP switch.
on the system
2. Press the FAUILT
reset.
controller?
RESET switch.
Yes
Apply power to the
applicable ROWPU,
Press the FRESH FLUSH
and press STOP and
switch on the applicable
FAULT RESET on the
system controller.
system controller.
WARNING:
Does
Take great care
the flush
Is
when working around
pump start, and
24 Vdc
Check for 24 Vdc
energized electrical
available to the Yes
does the FRESH
at the applicable
No
equipment. Contact
FLUSH indicator
applicable fresh
fresh water flush
between unprotected
illuminate on the
water flush
pump
body parts and
applicable
pump?
electrical box.
electrical conductors
control
can cause serious
panel?
injury or death.
No
Yes
B
To Sheet 2
A
To Sheet 2
Replace the faulty
fresh water flush
pump
Exit
Procedure 3. No Fresh Water Flow During Fresh Water Flush Cycle (Sheet 1 of 2)
0009 00-6