TM 55-1925-282-14&P
0012 00
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
c. The following media filter gauges:
(1) INLET PRESSURE
(2) OUTLET PRESSURE
OUTLET PRESSURE
INLET PRESSURE
7
After
0.5
Media Filter
Backflush and rinse media as required
to prevent differential pressure from
exceeding 20 PSI (1.4 bar)
8
Weekly
0.5
Media Filter
Backflush and rinse media as required
to prevent differential pressure from
exceeding 20 PSI (1.4 bar)
9
Monthly
0.2
5-Micron Filter
Verify that the filter housing is clean,
and replace the filter element if the
pressure differential across the filter
is greater than 10 PSI (0.7 bar)
10
Monthly
0.2
20-Micron Filter
Verify that the filter housing is clean,
and replace the filter element if the
pressure differential across the filter
is greater than 10 PSI (0.7 bar)
0012 00-3