TM 55-1925-282-14&P
0024 00
3
5
6
2
1
7
4
Figure 7. Fresh Water Flush Diverter Valve
INSTALLATION
1. Wrap the male threads of the pipe fittings (figure 7, item 7) with four wraps of antiseizing tape.
2. Thread the pipe fittings (figure 7, item 7) into place on the fresh water flush diverter valve (figure 7, item 3),
and tighten snugly into place.
3. Position the fresh water flush diverter valve (figure 7, item 3) on its foundation, and secure it in place with four
screws (figure 7, item 5) and four flat washers (figure 7, item 6).
4. Connect the piping (figure 7, item 4) to the fresh water flush diverter valve (figure 7, item 3).
5. Slide the wire plug (figure 7, item 2) onto the fresh water flush diverter valve (figure 7, item 3), and secure it
in place with the screw (figure 7, item 1).
6. Perform the Follow-On Service procedure at the end of this work package.
REPLACE PRODUCT WATER DIVERTER VALVE
REMOVAL
2. At 440V power panel No. 5, set to OFF, lock out, and tag out (FM 55-502) the applicable circuit breaker as
shown in table 1.
3. At the 24 Vdc control panel, set to OFF, lock out, and tag out (FM 55-502) the applicable circuit breaker as
shown in table 1.
0024 00-17