TM 55-1925-284-14&P
0023 00
WARNING
Replace or repair components only after the affected circuit has been secured,
locked out, and tagged out. Performing replacement with the circuit energized
may result in injury.
4. Check for available voltage at the wiring (figure 1, item 4). If voltage is present, ensure that the proper circuit
breaker is secured, locked out, and tagged out (FM 55-502). If no voltage is present, continue with the
procedure.
5. Label and disconnect the wiring (figure 1, item 4) to the blower assembly motor (figure 1, item 3).
6. Remove the four nuts (figure 1, item 5) and the four lockwashers (figure 1, item 6) from the studs (figure 1,
item 7) that secure the blower assembly motor mounting plate (figure 1, item 8) to the foundation (figure 1,
WARNING
Heavy loads can crush. Do not allow any body parts to come under the load or
between the load and a stationary object. Death or serious injury can result.
7. Using two crewmembers, remove the blower assembly motor (figure 1, item 3) and the blower assembly
motor mounting plate (figure 1, item 8) from the foundation (figure 1, item 9).
8. Remove the four bolts (figure 1, item 10) that secure the blower assembly motor (figure 1, item 3) to the
blower assembly mounting plate (figure 1, item 8).
WARNING
Heavy loads can crush. Do not allow any body parts to come under the load or
between the load and a stationary object. Death or serious injury can result.
9. Using two crewmembers, remove the blower assembly motor (figure 1, item 3) from the blower assembly
mounting plate (figure 1, item 8).
0023 00-3