AUTOMATIC DRAINS
Each receiver is equipped with an automatic drain to prevent accumulation of condensate inside the receiver.
Technical characteristics of the drains are contained in table 5.
Table 5. Automatic Drain Technical Characteristics
Item
Data
Manufacturer ........................................................................................................ Arrow Pneumatic
Model ..................................................................................................................................... 5702S
Adjustable Cycle Time ............................................................................................. 1 to 60 minutes
Adjustable Drain Time ............................................................................................. 1 to 30 seconds
Maximum Working Pressure .............................................................................. 200 PSI (13.8 bar)
Maximum Fluid Temperature ..................................................................................... 165 F (74 C)
Ambient Temperature ................................................................................ 35 to 165 F (2 to 74 C)
Voltage ....................................................................................................... 115 Vac, 1 phase, 60 Hz
Amps ..................................................................................................................................... 0.25 A