TM 55-1925-286-13&P
0005 00
7. At 440V power panel no. 4, set the following circuit breakers to the OFF position:
a. AIR COMPRESSOR NO. 1 circuit breaker (figure 4, item 1).
b. AIR COMPRESSOR NO. 2 circuit breaker (figure 4, item 2).
8. Check that CA-47 STG AIR TK DR (figure 1, item 8) and CA-46 STG AIR TK DR valves (figure 1, item 9) are
CLOSED.
9. CLOSE valves CA-50 AUTO DR (figure 1, item 6) and CA-49 AUTO DR (figure 1, item 7).
10. CLOSE valves CA-11 STG AIR TK INL (figure 1, item 4) and CA-12 STG AIR TK INL (figure 1, item 5).
11. CLOSE CA-1 and CA-2 COV-COMPR DISCH valves (figure 2, item 3) and CA-87 and CA-88 COV-COMPR
DISCH valves (figure 2, item 4).
12. Check that CA-89 and CA-90 COV-COMPR DISCH valves (figure 2, item 1) and CA-93 andCA-94 MOIS-
TURE SEP DR valves (figure 2, item 2) are CLOSED.
13. CLOSE valves CA-4 STG AIR TK OUT (figure 1, item 1) and CA-3 STG AIR TK OUT (figure 1, item 2) at the
starting air receivers (figure 1, item 3).
END OF WORK PACKAGE
0005 00-6