TM 55-1925-286-13&P
0009 00
From
Sheet 1
Is 120 Vac
Warning:
available between
Take great care when working around
No
L1 (figure 1, item 1)
energized electrical equipment. Contact
and L2 (figure 1, item 2)
between unprotected body parts and
terminals on the
electrical conductors can cause serious
pressure
injury or death.
switch?
Yes
Is
450 Vac
available at L1,
Can the
Yes
Yes Replace the
L2, and L3 terminals
compressor be
electric motor
on the electric motor
rotated
(figure 2,
manually?
item 1)?
No
No
Notify maintenance
supervisor. Refer to
Troubleshoot the
direct support
motor controller
maintenance for air
(TM 55-1925-273-24&P).
Replace the
pressure switch
Exit
Procedure 1. Compressor Will Not Run (Sheet 2 of 2)
0009 00-3