Cleaning solvent is flammable and its vapor is potentially explosive. Do not use
cleaning solvent in the vicinity of spark, open flame, or excessive heat. Do not
use cleaning solvent in unventilated spaces. Failure to follow these precautions
can result in death or serious injury
! CAUTION
All remnants of the oil filter's sealing gasket must be removed from the oil filter's mount-
ing base prior to installing a new filter. Oil leakage and subsequent equipment damage
can result from failure to comply.
4. Use a clean wiping rag and dry cleaning solvent to clean the oil filter's mounting base. Ensure that no
remnants of the oil filter's sealing gasket (figure 2, item 1) remain on the mounting base.