TM 9-1550-416-14&P
(2)
Remove fueling probe from fitting on the fuel
ADJUSTMENT AND ALIGNMENT PRO-
2-12.
container cap
and connect it to the carburetor feed line.
CEDURES FOR SUPPORT EQUIPMENT.
(3)
Disconnect pressure line from muffler pres-
sure fitting.
There are no adjustment or alignment procedures required on
(4)
Set main power panel switch to ON.
the support equipment.
NOTE
FUELING PROCEDURES FOR FQM-117 B-1
2-13.
Fuel pump power panel switch is bidirectional and
AND FQM-117 C-1.
fuel will pump into or out of the fuel tank.
WARNING
(5) Operate power panel fuel pump switch in the
The fuel is flammable and burns clear. Use
direction necessary to pump fuel into the fuel tank.
only in well ventilated area. Extinguish all
(6) Continue pumping the fuel until fuel is ob-
flames and do not light matches or smoke
served coming from the pressure line.
while handling fuel.
(7) On the power panel, position the controls as
follows:
The equipment required to perform the fueling
a.
(a) Set fuel pump switch to OFF.
procedures are contained in the support equipment.
(b) Set power panel switch to OFF.
Procedures for fueling the aerial target are
b.
(8) Reconnect pressure line to muffler pressure
contained in this paragraph. The setup is shown in figure 2-
fitting.
14. Perform the following fueling
procedures.
(9) Disconnect fueling probe from carburetor line.
(10) Reconnect tubing from fuel tank tocarburetor.
(1)
Disconnect the fuel tubing from the carburetor.
Figure 2-14. FQM-117 B-1 and FQM-117 C-1 fueling procedures.
2-15