TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
x. SPECIAL PURPOSE KIT (CONT)
x1.
NO POWER TO DIGITAIZATION RACK (CONT)
(e)
Position master power switch to ON (para 2-27a or b).
If circuit breaker (CB1) trips again, notify Unit Maintenance.
If circuit breaker is not tripped, but there is still no power to MTS, notify Unit Maintenance.
(f)
Position master power switch to OFF (para 2-27f).
(g)
Position electrical distribution block cover on power distribution shelf.
(h)
Tighten wing screw on electrical distribution block cover.
(i)
Install wing screw in power distribution shelf.
NO POWER TO ENHANCED POSITION LOCATION REPORTING SYSTEM (EPLRS).
WARNING
Remove rings, brackelets, wristwatches, neck chains, and any other jewelry before
working around vehicle. Jewelry may catch on equipment or may short across an
electrical circuit. Failure to comply may result in serious injury or death to personnel.
Step 1. Check to see if circuit breaker (CB5) is tripped.
(a)
Remove wing screw from power distribution shelf.
(b)
Loosen wing screw on electrical distribution block cover.
(c)
Remove electrical distribution block cover from electrical distribution shelf.
Change 2