TM 9-2330-203-14&P
4-7. PMCS PROCEDURES (Con't).
(3) Electric Wires or Connectors. Inspect for cracked or broken insulation, bare wires, and loose or
broken connectors. Make repairs or replace as required.
(4) Hoses, Lines, and Fittings. Inspect for wear, damage, and leaks. Ensure that clamps and fittings are
tight. If a leak originates from a loose fitting or connector, tighten it. If a component is broken or worn, correct problem if
authorized by the Maintenance Allocation Chart (MAC) (Appendix B). If not authorized, report it to your supervisor.
h. The columns in Table 4-1 are defined as follows:
(1) Item No. The number in this column shall be used as a source of item numbers for the "TM ITEM NO."
column on DA Form 2404 in recording results of PMCS.
(2)
Interval. Tells you when to do a certain check or service.
(3)
Item to be Inspected. Lists system and common names of items that are to be inspected.
(4) Procedures. Tells you how to do a certain check or service.
TABLE 4-1. Organizational Preventive Maintenance Checks and Services (PMCS).
4-4