TM 9-2330-213-14&P
2-15. OPERATING 110-VOLT ELECTRICAL POWER SOURCE (M448) (Con't).
(2) Remove two leveling jacks (6) from stowed position. Place one leveling jack under each rear
corner of shop van trailer.
CAUTION
Leveling jacks (6) are used to provide support when personnel enter and exit trailer.
They must not be used to raise rear of trailer. Failure to follow this caution will result
in damage to leveling jacks.
(3) Remove Iockpin (5) and extend leveling jack (6) until rear of trailer is supported. Insert Iockpin
to hold leveling jack in extended position. Repeat for other leveling jack.
(4) Remove ground rod (7) from stowed position and drive into ground.
(5) Connect 110-volt auxiliary power cable (4) to receptacle (3).
(6) Turn electrical power on at circuit breaker (2).
(7) Plug electrical equipment into outlets (1) as needed for use.
b. Disconnecting.
(1) Turn off all electrical equipment and unplug from outlets (1).
(2) Turn off electrical power at circuit breaker (2).
(3) Disconnect 110-volt auxiliary power cable (4) from receptacle (3).
(4) Remove ground rod (7) from ground and stow.
(5) Remove Iockpin (5) and lower leveling jack (6). Insert Iockpin and stow leveling jack in shop van
trailer. Repeat for other leveling jack.
2-20