TM 9-2330-213-14&P
This Task Covers:
a.
Removal
Installation
b.
Initial Setup:
Equipment Conditions:
Materials/Parts:
q
q
Tools/Test Equipment:
q One gasket
General mechanic's tool kit
REMOVAL
a.
WARNING
Auxillary power cable must be disconnected from outside housing before
performing any work on 110-voit electrical system. Failure to folllw this warning may
result in injury or death.
NOTE
During removal, circuit breaker box (8) should be visually inspected for burnt wires,
arcing, damaged circuit breakers, and loose connections that may cause damage to
equipment. Wires should be visually inspected for damaged or broken insulation
that may cause shorting,
1.
Remove four screws (17) and cover (16) from junction box (11).
2.
Loosen four screws (14) at two receptacles (15). Tag two wire leads (3), ground wire lead (5), and
jumper wire (9).
3.
Disconnect two wire leads (3), ground wire lead (5), and jumper wire (9) from two receptacles (15).
4.
Remove two receptacles (15) from junction box (11).
5.
Remove connector (10) from conduit (4) and junction box (11).
6.
Remove two screws (13) and junction box (11) from wall (12).
7.
Remove four screws (1) from two hinges (2) and box (8).
Remove two setscrews (20), flatwashers (19), and cover (18) from box (8).
8.
9.
Loosen screw (6) which secures ground wire lead (5) to terminal board (7). Tag ground wire lead (5) and
two wire leads (3).
10.
Remove ground wire lead (5) from terminal board (7).