TM 9-2330-227-14&P
AIR LINES AND FITTINGS - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
REMOVAL - CONTINUED
NOTE
If removing left air line, the wrenches for air line from emergency relay valve to air
reservoir are 7/8-inch open-end box and 11/16-inch open-end wrenches.
Five nuts (3)
Using 5/8-inch open-end box wrench
14. Three air lines
and 9/16-inch open-end wrench, unscrew
(1) and five
and take off.
adapters (2)
Nut (5)
Using 5/8-inch open-end box wrench and
15. Elbow (4)
1/2-inch open-end wrench, unscrew and
take off.
Three air lines (1)
Take off.
16. Five adapters (2)
and elbow (4)
Five adapters (2)
Using 9/16-inch box-end wrench, unscrew
17. Adapter (6),
and take off.
air filter (7),
air chamber (8),
and relay
valve (9)
Elbow (4)
Using 1/2-inch open-end wrench, unscrew
and take off.
Nut (11),
a.
Using 11/4-inch and 11/2-inch
19. Adapter (6)
Iockwasher (12),
box-end wrenches, unscrew and
and frame
and tag (13)
take apart.
member (10)
Remove adapter (6) and tag (13) from
b.
frame member (10).
INSTALLATION
NOTE
New air tubing is manufactured to required length from bulk items. For information on
Put tag (13) and adapter (6) in place
Tag (13), Iockwasher
a.
20. Adapter (6)
(12), and nut (11)
in frame member (10).
and frame
b.
member (10)
Screw Iockwasher (12) and nut (11) in,
and tighten using 11/4-inch and
11/2-inch box-end wrenches.
4-120