TM 9-2330-227-14&P
CABLE BOX - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REPAIR - CONTINUED
WARNING
Drycleaning solvent PD-680 is both toxic and flammable. Avoid prolonged breathing of
vapors, and avoid skin contact. Use only in well-ventilated area, and keep away from
open flame or excessive heat. Injury to personnel could occur.
a. Using PD-680 drycleaning solvent and
Lid (5)
9.
brush, clean area for strips (13).
b. Wipe with rag, and let dry.
a. Put adhesive on lid (5).
Four strips (13)
10. Lid (5)
b. Put strips (13) in place.
Put in place.
Latch (3)
11. Box (1)
Pop in place using hand riveter.
Four rivets (12)
12. Latch (3) and
box (1)
Put in place.
Hasp (2)
13. Lid (5)
Pop in place using hand riveter.
Two rivets (11)
14. Hasp (2) and
lid (5)
Put in place.
Chain (6) with
15. Box (1)
hook (4)
Screw in, and tighten using number two
Washer (8), screw
16. Chain (6) and
offset cross-tip screwdriver and 12-inch
(7), Iockwasher (9)
box (1)
adjustable wrench.
and nuts (10)
a. Close lid (5) and hasp (2).
Hook (4) and
17. Box (1), hasp (2),
b. Put hook (4) in place.
lid (5)
and latch (3)
4-171