TM 9-2330-227-14&P
INSIDE PANELING AND INSULATION - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
NOTE
All paneling and insulation is removed the same way. This task is for one panel and
piece of insulation. Repeat this task for the others, noting number of screws and
particular equipment condition required.
REMOVAL
33 screws (4)
Using number two cross-tip screwdriver,
1. Molding (1) and
unscrew and take off.
panels (2) and (3)
Molding (1)
a. Take off.
2. Panels (2) and (3)
b. Repeat steps 1 and 2a for other side.
With assistant holding panel (2), and
33 screws (6)
3. Panel (2) and
and using number two cross-tip screw-
body bows (5)
driver, unscrew and take off.
Panel (2)
Take off.
4. Body bows (5)
Insulation (7)
Take off.
5.
INSTALLATION
6.
Insulation (7)
With aid of assistant, put in place,
and hold.
Panel (2)
7.
Put in place, and hold.
8. Panel (2) and
33 screws (6)
With aid of assistant, screw in and
body bows (5)
tighten using number two cross-tip
screwdriver.
Molding (1)
9. Panels (2)
Put in place.
and (3)
10. Molding (1) and
33 screws (4)
a. Screw in, and tighten using number two
panels (2)
cross-tip screwdriver.
and (3)