TM 9-2330-227-14&P
CONNECTOR RECEPTACLE REPAIR, 24-VOLT - CONTINUED
REPAIR - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE: lnstall 24-volt connector receptacle (page 4-74).
TASK ENDS HERE
WIRE HARNESS, 24-VOLT, DOMELIGHTS
This task covers:
INITIAL SETUP
Personnel Required
Tools
One
Screwdriver, flat-tip, 3/16-inch
Equipment Condition
Socket, 3/8-inch drive, 7/16-inch
Wrench, open-end, 7/16-inch
Insulation removed as required to access
Materials/Parts
ACTION
ITEM
LOCATION
REMARKS
NOTE
This harness is used only if the semitrailer is fitted with 24-volt domelights.
5-11