TM 9-2330-227-14&P
WIRE HARNESS, 24-VOLT, DOMELIGHTS - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
REMOVAL
20 screws (2)
Using 7/16-inch socket, ratchet handle
1. 20 clamps (1)
and nuts (3)
with 3/8-inch drive, and 7/16-inch
open-end wrench or 3/16-inch flat-tip
screwdriver, unscrew and take off.
Screws may be slotted or hex head.
20 clamps (1)
Using 3/16-inch flat-tip screwdriver, pry
2. Harness (4)
apart and take off.
Harness (4)
Take off,
3. Ceiling
INSTALLATION
Harness (4)
Place in position, and hold in place
4.
with tape.
5. Harness (4)
20 clamps (1)
a. Position at screw holes.
at frame (5)
b . Put on.
20 screws (2)
Screw together, and tighten using 7/16-
6. 20 clamps (1)
and frame (5)
and nuts (3)
inch socket, ratchet handle, and 7/16-
inch open-end wrench or 3/16-inch