TM 9-2330-246-14
4-19. 24-VOLT DOMELIGHT SWITCH AND JUNCTION BOX REPLACEMENT (M373A5)
(Con't).
INSTALLATION
b.
1.
Install junction box (1) using two screws (9).
2.
Install nut (3) on connector (2).
Install cover (4) using two screws (8).
3.
4.
Connect wires to switch (5) and remove tags.
Position switch (5) in cover (4) and junction box (1).
5.
Install wall plate (6) on junction box (1) with two screws (7).
6.
FOLLOW-ON TASKS:
q Connect
Check operation of domelights.
TA700163
4-30