4-82. SPRING HOLDER MAINTENANCE (Con't).
c.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
The solvent's flash point is 10OF-138F (38C-59C). If you become dizzy while
using cleaning solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes and get medical aid.
1.
Clean all metal parts with dry cleaning solvent and dry thoroughly.
2.
Inspect for bent, badly worn, deteriorated, or damaged parts. Replace all damaged parts.
a. ASSEMBLY
1.
Position bearing (8) in spring holder (2) and install
pin (9).
Install two setscrews (6) and new locknuts (7).
2.
Torque setscrews to 15-25 Ib.-ft. (20-34 Nm).
INSTALLATION
e.
1.
Position spring holder (2) on dolly (1) and install
bolt (3), new Iockwasher (4), and nut (5).
2.
Install seven collars (10) and pins (11) or new
rivets to secure spring holder (2) to dolly (l).
FOLLOW-ON TASKS:
TA700291