TM 9-2330-356-14
c.
Fuel Sampling.
(8) Adjust engine throttle for desired flow rate
NOTE
Additional Information on fuel sampling may
used. Unreel hose(s) completely.
be obtained from FM 10-68.
(10) Insert nozzle into vehicle being serviced, and
(1) Fuel sampling is done during filtered fuel
squeeze nozzle trigger to start flow.
dispensing operations. Fuel is removed through an
Aqua-Glo probe and adapter installed on outlet nipple of
(11) Release nozzle trigger at end of operation
and remove nozzle from vehicle.
(12) Adjust engine to idle speed (1000-1200 rpm).
sampling instructions.
2-17. Filtered Fuel Servicing Operations (M970
and M970A1 )
both hose reels at the same time. Tighten hose reel lock.
a. Filtered Self-Load. This operation is a means of
(14) Close all valves.
loading filtered fuel through the bottom of the tank. Fuel
is pumped from the storage facility through the
filter/separator, meter, 2-inch hose reel, and bottom
load adapter (fig. 2-34). Filtered self-load operation is as
follows:
WARNING
DO NOT let go of the static reel cable when
rewinding until the ball stop is firmly touching
WARNING
the reel. Failure to follow this warning may
cause injury to personnel.
Hose reel cabinet door is heavy-use two
hands when opening and closing. Use
(16) Disconnect static reel cable first from vehicle,
latches to lock door. Do not slam.
then from ground. Rewind static reel cable.
release cable and lift door with both hands.
(17) Cover and store fire extinguisher(s).
Figure 2-33. Hose Reel Cabinet With Door Closed (M970 and M970A1).