TM 9-2330-357-14&P
4-22. OUTRIGGER CONTROL PANEL MAINTENANCE (Con't).
f. DOOR HANDLE REMOVAL
1.
Remove nut (50), washer (51), two spacers
(52), and lever (53) from door handle (3).
2.
Pull door handle (3) and preformed packing
(55) from door (17).
3.
Remove preformed packing (55) from door
handle (3). Discard preformed packing.
4.
If damaged, remove rubber seal (54) from
around door (17) and discard.
g. CLEANING AND INSPECTION
_________
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles and gloves,
and use only In a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO NOT
breathe vapors. DO NOT use near open flame or excessive heat. The solvent's flash point is 100 -
F
138 (38 -59 ). If you become dizzy while using cleaning solvent, Immediately get fresh air and
F
C
C
medical help. If solvent contacts eyes, immediately wash your eyes and get medical aid.
1.
Clean all metal parts with a clean rag and dry cleaning solvent, and allow to dry.
2.
Clean all electrical parts and rubber parts with a clean rag.
3.
Inspect wiring for damage, deteriorated insulation, and broken or cracked connectors and insulators.
4.
Inspect all metal parts for scratches, marred paint, cracks, rust, or corrosion.
h. DOOR HANDLE INSTALLATION
1.
If removed, install new rubber seal (54) around door (17).
2.
Install new preformed packing (55) on door handle (3).
3.
Install door handle (3) and preformed packing (55) in door (17).
4.
Install two spacers (52), lever (53), washer (51), and nut (50) on door handle (3).
TA706443
4-28