TM 9-2330-357-14&P
4-56. STOWAGE BOX REPLACEMENT.
This Task Covers:
a. Removal
c. Installation
b. Cleaning and Inspection
Initial Setup:
Materials/Parts:
Tools/Test Equipment:
General mechanic's tool kit
Personnel Required: Two
Eight lockwashers
a. REMOVAL
1. Remove six screws (5) and lockwashers (4) from stowage box (3). Discard lockwashers.
2. Remove padlock. Open door (1), and remove two screws (7) and lockwashers (6). Discard lockwashers.
3. Remove stowage box (3).
b. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective
goggles and gloves, and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame or
excessive heat. The solvent's flash point is 100 -138 (38 -59 ). If you become
F
F
C
C
dizzy while using cleaning solvent, immediately get fresh air and medical help. If
solvent contacts eyes, immediately wash your eyes and get medical aid.
1. Remove all buildup of grease or dirt by using clean rag or medium bristle brush and dry cleaning solvent,
and allow to dry.
2. Inspect for loose, missing, or damaged hardware.
3. Inspect for cracks, holes, warps, dents, and bends.
4. Inspect for rust, corrosion, or marred finish.
4-116