TM 9-2330-371-14&P
WIRE HARNESS - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
INSTALLATION
Wire harness (3)
Lay out under semitrailer between main
Main beams (1)
32.
beams (1) and (2).
and (2)
Mark location on harness (3) with
a.
Antichafing
Wire harness (3)
33.
measurements taken from old harness.
material (4)
Cut antichafing material to size
b.
required.
Wrap around wire harness (3) in marked
c.
location.
Fasten by wrapping with three turns
d.
plastic tape every 4 inches.
Wire harness (3)
Run 5-foot long piece of stiff, soft
a.
Left main beam
34.
wire through boxed part of frame (5)
box (5) over
from rear to front.
bogies
b.
Attach wire to rear end of wire harness
(3) and pull through until rear of anti-
chafing material (4) is lined up with
harness clamp stud (6).
Remove wire from wire harness (3).
c.
Clamp (7)
Put on.
Wire harness (3)
35.
and harness clamp
stud (6)
Nut (8) and
Put on and tighten using 7/16-inch socket
Harness clamp
36.
Iockwasher (9)
and handle.
stud (6) and
harness clamp (7)