4-74. EMERGENCY VALVE OPERATOR MAINTENANCE (Con?).
CAUTION
DO NOT hold large fusible nuts (10) when tightening nuts (8). Fusible nuts
will strip if held.
Connect two cables (7) to emergency valve control lever (14) and vapor vent control lever
(4)
(9). Tighten two nuts (8).
Connect bottom cable (2) to vapor vent control lever (9). Install two nuts (4).
(5)
Connect top cable (2) to emergency valve control lever (14). Install two nuts (4).
(6)
Check operation of emergency valve operator (1). Adjust cable lengths, as required (see
(7)
ADJUSTMENT OF CABLES, subparagraph c).
4-242