TM 9-2330-386-14&P
4-22 WIRE CONNECTORS (CONT) .
d. Circuit Marker Band Replacement
U s i n g f l a t - t i p s c r e w d r i v e r , open tab ends (11) on marker band (12) . Remove
(1)
from wire lead (13), note circuit number, and discard marker band.
( 2 ) Etch proper number on new marker band (12).
(3) Place new circuit marker band (12) on
w i r e lead (13). Bend tab ends (11) over
wire lead.
(4) Connect power.
TASK ENDS HERE
4-23 12-VOLT RECEPTACLE (NOSE PLATE.)
This task covers removal and installation.
INITIAL SETUP
Tools
N o . 1 common tool kit
Electrical connector tool kit
a. Removal.
WARNING
Disconnect all electrical power before performing any
maintenance on the electrical system. Failure to do so
could result in injury.
CAUTION
Don't allow nose plate to drop or hang by wires. Support
n o s e plate to prevent damage to wires, connectors, and
tubing.
NOTE
If circuit marker bands are missing or not readable, tag
wire leads.
(1) Remove four capscrews (1) and carefully pull nose plate (2) away from
frame. Support nose plate (2).
4-36