TM 9-2330-386-14&P
4-24 24-VOLT RECEPTACLE (CONT).
(5) Insert wire ends (17) into back of
bushing (14) according to pin
p l a c e m e n t diagram.
(6) Strip insulation from wire ends (16)
equal to depth of solder well in pins
(13). Place wire end (16) in solder
(7) Apply insulating compound to rubber
g r o m m e t in receptacle ( 15).
(8) Install pins (13) in receptacle (15) grommet according to pin placement
diagram.
(9) Slide bushing (14) down harness wires (17) and position over pins (13).
c.Installation.
(1) Position receptacle harness (12) on nose plate (2).
(2) Slide nut (9) on wires and install on receptacle. Tighten nut (9).
(3) Install cover (11) and four capscrews (10) and tighten.
(4) Connect three receptacle harness connectors (6) to main wiring harness and
three connectors (7) to resistors (8).
(5) Install three ground wires (5), lock washers (4), and nuts (3). Tighten
nuts (3).
( 6 ) Guide wires and tubing into frame opening and position nose plate (2)
against frame.
( 7 ) I n s t a l l a n d t i g h t e n f o u r capscrews (1).
power and check for proper operation.
(8)
Connect
electrical
TASK END HERE