TM 9-2330-388-14
2-14.
Stopping The Engine
1.
Idle engine before stopping by pushing throttle
lever in fully down position.
2.
Turn ignition off.
3.
Figure 2-15. Throttle and Stop Lever Adjustments
2-16.
Filling Own Tank From Source Not Under
Pressure
NOTE
If the pump is used to move potable water
from an external source that Is at a lower
level and not under pressure the operation is
termed "working from draft".
1.
Check level of water in tank. It must at least fill
the pipes and emergency valve. If not, the pump must
Figure 2-14. Control Panel-Stopping the Engine
be primed, by opening emergency valve and filling
2-15.
Engine Run-on
2.
Close emergency valve. Close both gravity
If engine does not stop when stop lever is
discharge valves, discharge valve and any other outlet.
pushed to the "stop" position, the inner cable may have
broken, come loose, or be out of adjustment. To stop
3.
Attach inlet hose to one of the discharge valves
the engine, use engine run-on stop tool, mounted on
with the other end at the source of water.
main discharge valve handle or push a small screw
driver or rod of approximately 1/8-inch diameter through
4.
Attach outlet hose to discharge valve and place
the small hole near where the throttle cable (upper cable)
other end in top opening.
goes into the engine. Immediately inside this hole is an
internal lever. Push this lever in as far as it will go and
2-10