Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
ONE OR MORE REAR
4.
Open cover on voltage
MARKER LIGHTS DO NOT
converter box (WP 0053
ILLUMINATE - CONTINUED
5.
Connect positive (+) probe
of digital multimeter to
terminal lug TL266.
6.
Connect negative (-) probe
of digital multimeter to
terminal lug TL261.
7.
Note reading on digital
multimeter.
8.
If continuity is not present,
repair wire (WP 0043 00). or
replace electrical cable
assembly (WP 0051 00). If
continuity is present, replace
right rear marker light
assembly (WP 0050 00).
9.
Close cover on voltage
converter box (WP 0053
0036 00-7


 