Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
ONE OR MORE REAR
6.
Connect positive (+) probe
MARKER LIGHTS DO NOT
of digital multimeter to
ILLUMINATE - CONTINUED
connector J253.
7.
Connect negative (-) probe
of digital multimeter to
connector J254.
8.
Note reading on digital
multimeter.
9.
If continuity is not present,
repair wire (WP 0043 00) or
replace electrical cable
assembly (WP 0051 00).
9.
Check for continuity between
1.
Set digital multimeter to
terminal lug TL265 and
ohms.
terminal lug TL264.
2.
Connect positive (+) probe
of digital multimeter to
terminal lug TL265.
3.
Connect negative (-) probe
of digital multimeter to
terminal lug TL264.
4.
Note reading on digital
multimeter.
0036 00-13


 