Custom Search
|
|
|
||
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
BOTH FRONT MARKER
3.
Check for continuity between
1.
Disconnect connector J250
LIGHTS DO NOT
connector J250 and terminal
from right front marker light
ILLUMINATE - CONTINUED
lug TL255.
connector.
2.
Open voltage converter box
cover (WP 0053 00).
3.
Set digital multimeter to
ohms.
4.
connect positive (+) probe
of digital multimeter to
connector J250.
5.
Connect negative (-) probe
of digital multimeter to
terminal lug TL255 and
note reading on digital
multimeter.
6.
If continuity is not present,
repair wire between terminal
lug TL263 and terminal lug
TL260 (WP 0043 00) or
replace electrical cable
assembly (WP 0051 00).
0036 00-34
|
||