Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7.
RIGHT STOPLIGHT DOES
5.
Connect negative (-) probe
NOT ILLUMINATE -
of digital multimeter to
CONTINUED
terminal lug TL252 and not
reading on digital
6.
If continuity is not present,
repair wire between
connector J259 and terminal
lug TL252 (WP 0043 00) or
replace electrical cable
assembly (WP 0051 00). If
continuity is present replace
voltage converter box (WP
7.
Close voltage converter box
8.
connect connector J259 to
right stoplight connector.
0036 00-52


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business