Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
RIGHT BLACKOUT
8.
If 18-26 vdc is not present,
STOPLIGHT DOES NOT
go to step 4 of this
ILLUMINATE - CONTINUED
malfunction.
9.
Install blackout stoplight in
socket.
10. Install preformed packing
and cover with six screws.
3.
Check to see if continuity is
1.
Set digital multimeter to
present between terminal lug
ohms.
TL269 and a known good
ground.
2.
Connect positive (+) probe
of digital multimeter to
terminal lug TL269.
3.
Connect negative (-) probe
of digital multimeter to a
known good ground and
note reading on digital
multimeter.
4.
If continuity is not present,
replace composite taillight
assembly (WP 0049 00).
0036 00-60


 


Privacy Statement - Copyright Information. - Contact Us