Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10. LEFT TAILLIGHT DOES NOT
4.
Check to see if continuity is
1.
Set digital multimeter to
ILLUMINATE - CONTINUED
present across circuit breaker
ohms.
CB3.
2.
Connect positive (+) probe
of digital multimeter to one
terminal of circuit breaker
CB3.
3.
Connect negative (-) probe
of digital multimeter to other
terminal of circuit breaker
CB3 and note reading on
digital multimeter.
4.
If continuity is not present,
replace circuit breaker CB3
0036 00-67


 