Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. LEFT BLACKOUT TAILLIGHT
2.
Check to see if continuity is
1.
Open voltage converter box
DOES NOT ILLUMINATE -
present across circuit breaker
CONTINUED
CB5.
2.
Set digital multimeter to
ohms.
3.
Connect positive (+) probe
of digital multimeter to one
terminal of circuit breaker
CB5.
4.
Connect negative (-) probe
of digital multimeter to other
terminal of circuit breaker
CB5 and note reading on
digital multimeter.
5.
If continuity is not present,
replace circuit breaker CB5
0036 00-78


 