BRAKE SYSTEM TROUBLESHOOTING - Continued
0037 00
BRAKE SYSTEM - Continued
Table 1. Brake System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8.
Check to see if continuity is
1.
Open voltage converter box
14. ANTI-LOCK BRAKING
present between ABS POWER
SYSTEM (ABS) DIAGNOSTIC
connector pin 1 and ground
TOOL BLINKS 10 TIMES IN
post terminal lug.
SERIES: ABS MODULATOR
VALVE FAULT - CONTINUED
2.
Set digital multimeter to
ohms.
3.
Connect positive (+) probe
of digital multimeter to ABS
POWER connector pin 1.
4.
Connect negative (-) probe
of digital multimeter to
ground post terminal lug.
5.
If continuity is not present,
replace ABS control power
6.
If continuity is present,
replace voltage converter