CLEARANCE AND MARKER LIGHT ASSEMBLIES
0050 00
REPLACEMENT - Continued
CLEARANCE AND MARKER LIGHT INSTALLATION (Incandescent Model) - Continued
1.
Install gasket (19) on base (3).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off
harmful vapors, and are harmful to skin and clothing. Keep away from open fire
and use in a well-ventilated area. If adhesive, solvent, or sealing compound
gets on skin or clothing, wash immediately with soap and water. Failure to
comply may result in injury to personnel.
2.
Apply adhesive to threads of screw (18).
3.
Install screw (18) in base (3) with lockwasher (17), nut (16), terminal lug TL266 (15), lockwasher (14),
and nut (13).
4.
Connect connector J254 (12) to plug (11).