TM 9-2330-398-10
2-19.
BASIC BULK HAUL AND FUEL-SERVICING OPERATIONS NOT INVOLVING USE OF ENGINE AND PUMP
(continued).
11.
When tank is full, fuel flow should stop automatically. Close all valves. Disconnect hose from bottom loading
connection (12) and install cover (11). Drain hose into suitable container.
12.
WARNING
DO NOT let go of static reel grounding cable when rewinding until ball stop is firmly touching reel.
Failure to follow this warning may cause injury to personnel.
13.
Disconnect static reel grounding cable (15) from ground rod (16) (Item 20, Appendix B) or suitable ground.
14.
Store and cover fire extinguishers (6).
C.
GRAVITY UNLOAD
1.
NOTE
Operation begins and ends with all valves closed.
2.
Make sure all valves are closed.
3.
Connect static reel grounding cable (15) to ground rod (16) (Item 20, Appendix B) or suitable ground.
4.
Disconnect spring pins and turn hose trough bars out of the way to remove 4-inch (10.16-cm) bulk delivery hose(s)
from trough.
2-49