TM 9-2350-222-10-2
ZERO SIGHTS (PERFORM INITIAL ZERO) - Continued
Loader:
possible, use ammunition of same lot number for all rounds fired
during zeroing.
Gunner:
16.
Using MANUAL TRAVERSE handle (J) and MANUAL
ELEVATION CONTROL handle (K), aline reticle 600 meter
aiming cross (L) on target aiming point (C) using G-box
method.
17.
Wait for commander's order to fire. Upon order to fire:
a.
Set MAIN GUN switch (M) to ON.
b.
Press either firing trigger (N).
c.
Set MAIN GUN switch (M) to OFF.
18.
After firing, use MANUAL TRAVERSE handle (J) and
MANUAL ELEVATION CONTROL handle (K) to aline reticle
600 meter aiming cross (L) on target aiming point (C) using G-
box method.
TA132580
2-440