TM 9-2350-222-10-2
OPERATE UNDER UNUSUAL CONDITIONS (PERFORM DEEP WATER FORDING)- Continued
10. If water reaches top of pump screen (A), set BILGE PUMP switch
(B) to ON.
CAUTION
Maintain 1500 rpm when shifting to reverse.
11.
vehicle crew keeps winch cable tight.
12.
Set BILGE PUMP switch (B) to OFF.
13.
Stop vehicle.
14.
Disconnect recovery vehicle tow cable.
15.
Stop engine.
16.
Check for leaks. If there are leaks, apply more sealer or tighten
clamps to stop leaks.
17.
Stow unused deep water fording kit items and checklist in left rear
fender box (C).
18.
Stow 25-pound can of sealer (D) in bustle cargo storage rack.
TA252908
Change 1 2-668.34