TM 9-2350-222-10-3
MAINTAIN TRACK (ADJUST TRACK TENSION -
GREASE ACTUATED ADJUSTING LINK) - Continued
NOTE
Threaded locking collar (J) may require tightening to break loose
trapped dirt prior to loosening.
7.
Pump grease into grease actuated adjusting link until grease exits
from pressure relief valve (F).
8.
Tighten threaded locking collar (J), using spanner wrench (A).
9.
Disconnect lubrication extension (C) from grease fitting (G).
10.
Remove lubrication extension (C) and grease gun (B).
11.
Repeat steps 1 through 10 above, for opposite side of tank.
12.
Repeat steps 1 through 11 two more times (a total of three tension
adjustments for each side of tank, made alternately).
NOTE
Do not make successive tension adjustments on same side of tank.
Always alternated sides.
TA249242
3-90.2
Change 2