TM 9-2350-222-10-3
MAINTAIN TURRET (SERVICE EQUILIBRATOR HYDRAULIC RESERVOIR)
Supplies:
NOTE
During steps 1 thru 3 if pressure gage
(A) reads less than 1375 psi before
precharge is low. Notify organiza-
tional maintenance.
Locate hand pump (B).
1.
Turning handle (C) one
2.
turn counterclockwise,
open drain valve.
Watch pressure gage (A)
3.
until pressure drops to
zero.
4 . Remove dipstick (D)
from hydraulic reservoir
(E) and wipe dry.
TA133092