TM 9-4110-246-14
TO 40R7-5-10-1
3-14.
REPLACEMENT OF RIGHT, CENTER, AND LEFT CEILING PANEL ASSEMBLIES, AND DOOR CANOPY.
TOOLS: Hex Wrench
REMOVAL
1. Remove sealing tape from top and side joints of ceiling panel assembly requiring replacement.
2. Unlock camlocks, as applicable, on ceiling panel assembly to be removed and/or on adjacent ceiling panel
assembly using hex wrench.
3. Unlock camlocks on ceiling ends of supporting wall structure panel assembly(s) as applicable.
4. Remove ceiling panel assembly requiring replacement.
5. To remove door canopy, remove applicable ceiling panel assemblies per steps 1 through 3, above. Then
remove door canopy.
INSTALLATION
CAUTION
Exercise caution when installing a panel assembly to prevent damage to camlocks
and gasket panels on replacement assembly and on connecting panel assemblies.
Be sure camlocks on replacement assembly and connecting panel assemblies are
fully retracted before positioning the replacement panel assembly.
1. Position replacement ceiling panel assembly gasket side down on refrigerator. If door canopy is being replaced,
first hang door canopy over door frame panel assembly.
3-18