TM 9-4110-254-14
4-35. RESET BUTTON REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts.
General Safety Instructions,
Lock Washers (2)
WARNING
Equipment Conditions.
High voltage and exposed rotating parts are
used m the refrigeration unit. Personal injury
can result if power is connected
disconnected
Control box cover door raised and latched.
a. Removal
(1)
Be sure power has been disconnected at the source and remove two bolts (1) and lock washers (2). Open
control panel (3). Discard lock washers.
NOTE
Mounting hardware is supplied with reset button.
(2)
Remove self locking nut (4) and remove reset button (5).
Figure 4-30. Reset Button
4-79