TM 9-4110-256-14
Table 2-1. Preventive Maintenance Checks and Services for Model F1000RE
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
41
Monthly
Wire lead frayed or
leads and loose or missing terminal cover.
broken, cover missing,
Inspect the sight glass for cracks. Inspect for
sight glass cracked or
evidence of refrigerant leak. Inspect shut off
evidence of leak is found.
valves for evidence of refrigerant leak. If wire
leads are frayed or broken, notify unit
maintenance to repair or replace it as necessary.
If damaged or evidence of leaking found, notify
direct support maintenance to repair or replace
it as necessary.
42
Monthly
Strainer
Inspect the strainer for dents or evidence of
Strainer is dented or
refrigerant leak. If damaged or evidence of
evidence of leak is found.
leaking found, notify direct support maintenance
to replace it.
2-18